The Raynor ControlHoist™ Standard is medium-duty, belt-drive operator, designed for high cycle applications and use on standard to larger size sectional doors, rolling door and grilles. Innovative features, along with durable mechanical design, offer a consistent and reliable performance day in and day out.

Standard Features

Entrapment: UL 325 2010 requires all commercial operators to use constant pressure to close or be equipped with an approved monitored entrapment protection device, such as a monitored photo eye or reversing edge. All ControlHoist Standard operators are provided standard with constant pressure to close. Up to two (2) monitored entrapment devices can be selected. In addition, a non-monitored entrapment device can also be selected.

LCD (Liquid Crystal Display): The 16 character LCD display allows for easy programming with an intuitive setup menu. Status indicators provide real-time status and display error messages for easy troubleshooting assistance.

Cycle Counter: LCD (Liquid Crystal Display) clearly indicates the exact number of cycles logged for easy maintenance support.

Programmable Mid-Stop: Adjustable from 3-30 seconds, this feature enables partial opening of the door to a preprogrammed position for energy savings, time savings, and convenience.

Timer-To-Close: Closes the door automatically after a predetermined amount of time has elapsed, for security and convenience.

Ventilation Feature: When a device such as a CO detector is activated, the door will partially open for a pre-determined amount of time. Once the CO detector is clear, the door will close.

Fire Station Timer: Ideal for fire stations. A push button or pull cord can be used to activate the open cycle and timer to close feature. Only the push button or pull cord will control the timer to close.

Motor: Continuous-duty, overload protected motor with high starting torque.

Drive Reduction: Primary reduction is a belt drive. Secondary reduction is by chain and sprocket.

Electro Magnetic Brake System: 24V DC brake. Fewer mechanical parts for improved reliability. (The 24V brake comes standard on all Optima and Standard models except for the ⅓ an ½ HP CST models, they are optional)

Adjustable Friction Clutch: Helps to protect the door and operator from damage should it come into contact with any obstruction.

3-Button Control Station: Provides open/close/stop functions.

Exterior Radio Control Terminal: Provides for fast and easy connection of radio controls. When the range is an issue, an optional external mounted radio receiver allows the flexibility for the receiver to be moved to a new location for improved range.

Product Details

Operation Mode Trolley, Dual Trolley, or Jackshaft with or without Hoist
Duty Cycle 30 Cycles/Hour
Operational Speed 8″ to 12″ per second
Drive Belt
Environmental Options NEMA 1, NEMA 7, NEMA 9 and NEMA 12
Motor Continuous Duty – 1/3, 1/2, or 3/4 hp
Logic Solid State
Circuit Board Solid State Logic with LCD Display
Power 120/240V 1-Phase 208/240/480V/575V 3-Phase
Brake Standard on Jackshaft and 3/4 hp Trolley models Optional on 1/3 and 1/2 hp Trolley models
Wiring Options 24V Class 2, On-Board Selection
Radio Receiver Optional
Radio Transmitter Optional
Warranty 3 years with purchase of door 2 years with purchase of operator only
Raynor Advantage Easily configure the correct operator with a door for a total Raynor branded system with an extended extra year of warranty.

 

Options

Auxiliary Board

Provides auxiliary contacts for when the door is in motion and at the open and close limits. The auxiliary board provides but is not limited to the following features:

  • Courtesy Light which illuminates whenever the door is activated
  • Capability to tie into Horn & Strobes for ADA compliance
  • Capability to tie a Traffic Light to provide safe entering and exiting of the facility
  • Security feature which allows the ability to connect to a facilities security system

Product Literature

 

Installation Instructions


Jackshaft Installation Instructions

Trolley Installation Instructions

ControlHoist Warranty

Raynor warrants the electrical operator and component parts for two (2) years against defects in material and workmanship.

Raynor warrants the electrical operator and component parts against defects in material and workmanship for three (3) years, on the operator only, when purchased with any model of Raynor commercial sectional or rolling door.

Under the terms of this limited warranty, for any operator components that are found to be defective upon inspection by authorized Raynor personnel, Raynor will, at its option, repair or replace the defective door components. Labor charges for installations or repairs shall be the responsibility of the consumer and must be performed by an authorized Raynor Dealer. This warranty applies only to doors that are professionally installed by an authorized Raynor Dealer.

This warranty extends only to the original purchaser. This warranty is not transferable.

This warranty does not apply to any damage or deterioration caused by abuse or failure to provide reasonable and necessary maintenance.

Raynor shall not be liable for any consequential or incidental damages.

ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY WARRANTY OF MERCHANTABILITY, ARE HEREBY EXPRESSLY EXCLUDED.

Some states do not allow the exclusion or limitation of consequential or incidental damages, so the above limitation or exclusion may not apply to you.

Claims for defects in material and workmanship covered by this warranty shall be made in writing with proof of purchase to the dealer from whom the product was purchased or call Raynor at 1-800-4-RAYNOR within the warranty period. Raynor may choose to have the product returned for inspection.

This warranty gives you specific legal rights. You may also have other rights, which may vary from state to state.